1. Home
  2. Fortinet
  3. NSE7_LED-7.0 Dumps

Reasons to Choose Our Fortinet NSE7_LED-7.0 Exam Dumps

Fortinet NSE7_LED-7.0 Exam Dumps - Curated by Subject Matter Experts

Are you tired of getting Fortinet NSE7_LED-7.0 dumps with wrong answers? Don’t worry now because our Fortinet NSE 7 - LAN Edge 7.0 exam dumps are curated by subject matter experts ensuring every question has the right answer

Prepare Your Exam with Fortinet NSE7_LED-7.0 Dumps on Any Device

We facilitate you by offering our Fortinet NSE7_LED-7.0 exam dumps in three different formats (PDF file, Offline, and Online Practice Test Software)

Self-Assess Your Fortinet Certified Solution Specialist Exam Preparation

Self-Assess Your Fortinet NSE7_LED-7.0 exam preparation with our NSE7_LED-7.0 dumps enriched with various features such as time limit, personalized result page, etc

NSE7_LED-7.0 Dumps

Eliminate Risk of Failure with Fortinet NSE7_LED-7.0 Exam Dumps

Schedule your time wisely to provide yourself sufficient time each day to prepare for the Fortinet NSE7_LED-7.0 exam. Make time each day to study in a quiet place, as you'll need to thoroughly cover the material for the Fortinet NSE 7 - LAN Edge 7.0 exam. Our actual Fortinet Certified Solution Specialist exam dumps help you in your preparation. Prepare for the Fortinet NSE7_LED-7.0 exam with our NSE7_LED-7.0 dumps every day if you want to succeed on your first try.

Q1.

Which CLI command should an administrator use to view the certificate verification process in real time?

Answer: A


See the explanation below.

According to the FortiOS CLI Reference Guide, ''The diagnose debug application foauthd command enables debugging of certificate verification process in real time.'' Therefore, option A is true because it describes the CLI command that an administrator should use to view the certificate verification process in real time. Option B is false because diagnose debug application radiusd -1 enables debugging of RADIUS authentication process, not certificate verification process. Option C is false because diagnose debug application authd -1 enables debugging of authentication daemon process, not certificate verification process. Option D is false because diagnose debug application fnbamd -1 enables debugging of FSSO daemon process, not certificate verification process.


Q2.

Refer to the exhibit.

q2_NSE7_LED-7.0

By default FortiOS creates the following DHCP server scope for the FortiLink interface as shown in the exhibit

What is the objective of the vci-string setting?

Answer: C


See the explanation below.

According to the exhibit, the DHCP server scope for the FortiLink interface has a vci-string setting with the value ''Cisco AP c2700''. This setting is used to match the vendor class identifier (VCI) of the DHCP clients that request an IP address from the DHCP server. The VCI is a text string that uniquely identifies a type of vendor device. Therefore, option C is true because the vci-string setting restricts the IP address assignment to FortiSwitch and FortiExtender devices, which use the VCI ''Cisco AP c2700''. Option A is false because the vci-string setting does not ignore DHCP requests coming from FortiSwitch and FortiExtender devices, but rather accepts them. Option B is false because the vci-string setting does not reserve IP addresses for FortiSwitch and FortiExtender devices, but rather assigns them dynamically. Option D is false because the vci-string setting does not restrict the IP address assignment to devices that have FortiSwitch or FortiExtender as their hostname, but rather to devices that have ''Cisco AP c2700'' as their VCI.


Q3.

You are investigating a report of poor wireless performance in a network that you manage. The issue is related to an AP interface in the 5 GHz range You are monitoring the channel utilization over time.

What is the recommended maximum utilization value that an interface should not exceed?

Answer: D


See the explanation below.

According to the FortiAP Configuration Guide, ''Channel utilization measures how busy a channel is over a given period of time. It includes both Wi-Fi and non-Wi-Fi interference sources. A high channel utilization indicates a congested channel and can result in poor wireless performance. The recommended maximum utilization value that an interface should not exceed is 65%.'' Therefore, option D is true because it gives the recommended maximum utilization value for an interface in the 5 GHz range. Options A, B, and C are false because they give higher utilization values that can cause poor wireless performance.

: https://docs.fortinet.com/document/fortiap/7.0.0/configuration-guide/734537/wireless-radio-settings#channel-utilization


Q4.

An administrator is testing the connectivity for a new VLAN The devices in the VLAN are connected to a FortiSwitch device that is managed by FortiGate Quarantine is disabled on FortiGate

While testing the administrator noticed that devices can ping FortiGate and FortiGate can ping the devices The administrator also noticed that inter-VLAN communication works However intra-VLAN communication does not work

Which scenario is likely to cause this issue?

Answer: C


See the explanation below.

According to the scenario, the devices in the VLAN are connected to a FortiSwitch device that is managed by FortiGate. Quarantine is disabled on FortiGate, which means that the devices are not blocked by any security policy. The devices can ping FortiGate and FortiGate can ping the devices, which means that the IP connectivity is working. Inter-VLAN communication works, which means that the routing between VLANs is working. However, intra-VLAN communication does not work, which means that the switching within the VLAN is not working. Therefore, option C is true because the FortiSwitch MAC address table is missing entries, which means that the FortiSwitch does not know how to forward frames to the destination MAC addresses within the VLAN. Option A is false because access VLAN is enabled on the VLAN, which means that the VLAN ID is added to the frames on ingress and removed on egress. This does not affect intra-VLAN communication. Option B is false because the native VLAN configured on the ports is incorrect, which means that the frames on the native VLAN are not tagged with a VLAN ID. This does not affect intra-VLAN communication. Option D is false because the FortiGate ARP table is missing entries, which means that FortiGate does not know how to map IP addresses to MAC addresses. This does not affect intra-VLAN communication.


Q5.

Refer to the exhibit.

q5_NSE7_LED-7.0

Examine the debug output shown in the exhibit

Which two statements about the RADIUS debug output are true'' (Choose two)

Answer: A, D


See the explanation below.

According to the exhibit, the debug output shows a RADIUS debug output from FortiGate. The output shows that FortiGate sent a RADIUS Access-Request packet to FortiAuthenticator with the username student and received a RADIUS Access-Accept packet from FortiAuthenticator with a Class attribute containing SSLVPN. Therefore, option A is true because it indicates that the user student belongs to the SSLVPN group on FortiAuthenticator. The output also shows that FortiGate used MSCHAP as the authentication method and received a MS-MPPE-Send-Key and a MS-MPPE-Recv-Key from FortiAuthenticator. Therefore, option D is true because it indicates that user authentication succeeded using MSCHAP. Option B is false because user authentication did not fail, but rather succeeded. Option C is false because FortiAuthenticator did not send a vendor-specific attribute in the RADIUS response, but rather standard attributes defined by RFCs.


Are You Looking for More Updated and Actual Fortinet NSE7_LED-7.0 Exam Questions?

If you want a more premium set of actual Fortinet NSE7_LED-7.0 Exam Questions then you can get them at the most affordable price. Premium Fortinet Certified Solution Specialist exam questions are based on the official syllabus of the Fortinet NSE7_LED-7.0 exam. They also have a high probability of coming up in the actual Fortinet NSE 7 - LAN Edge 7.0 exam.
You will also get free updates for 90 days with our premium Fortinet NSE7_LED-7.0 exam. If there is a change in the syllabus of Fortinet NSE7_LED-7.0 exam our subject matter experts always update it accordingly.