1. Home
  2. Exin
  3. CDCP Dumps

Reasons to Choose Our Exin CDCP Exam Dumps

Exin CDCP Exam Dumps - Curated by Subject Matter Experts

Are you tired of getting Exin CDCP dumps with wrong answers? Don’t worry now because our Certified Data Centre Professional Exam dumps are curated by subject matter experts ensuring every question has the right answer

Prepare Your Exam with Exin CDCP Dumps on Any Device

We facilitate you by offering our Exin CDCP exam dumps in three different formats (PDF file, Offline, and Online Practice Test Software)

Self-Assess Your Data Centre Professional Exam Preparation

Self-Assess Your Exin CDCP exam preparation with our CDCP dumps enriched with various features such as time limit, personalized result page, etc

CDCP Dumps

Eliminate Risk of Failure with Exin CDCP Exam Dumps

Schedule your time wisely to provide yourself sufficient time each day to prepare for the Exin CDCP exam. Make time each day to study in a quiet place, as you'll need to thoroughly cover the material for the Certified Data Centre Professional Exam . Our actual Data Centre Professional exam dumps help you in your preparation. Prepare for the Exin CDCP exam with our CDCP dumps every day if you want to succeed on your first try.

Q1.

What is a requirement of an FM200 (HFC-227) installation?

Answer: A


See the explanation below.

FM200 (HFC-227) is a clean agent fire suppression system that uses a high-pressure gas to extinguish fires by reducing the oxygen concentration and absorbing the heat. FM200 is stored in cylinders at pressures of up to 42 bar (600 psi) and is released through nozzles into the protected area. Because of the high pressure, the nozzles must be mounted with two brackets to prevent them from moving or breaking during discharge. The brackets must be securely attached to the ceiling or wall and aligned with the nozzle outlet. The nozzle outlet must also be free of any obstructions that could affect the discharge pattern or distribution.


* EPI Data Centre Professional (CDCP) Preparation Guide, page 32

* FSL-227 Technical Manual, page 10

* Firetrace ILP Manual, page 21

Q2.

What is the recommended location for the Isolation Transformer in relation to the ICT-Equipment location?

Answer: A


See the explanation below.

According to the EPI Data Centre Training Framework, an isolation transformer is a device that transfers electrical power from one circuit to another without changing the voltage or frequency, but providing galvanic isolation1. Galvanic isolation means that there is no direct electrical connection between the input and output circuits, which can prevent ground loops, reduce noise, and improve safety2. An isolation transformer can also provide voltage stepdown or stepup, create a local ground-bonded neutral, reduce harmonic currents, and provide taps for abnormal mains voltage3.

The location of the isolation transformer in relation to the ICT equipment depends on the purpose and design of the transformer. In general, the isolation transformer should be as close as possible to the ICT equipment, but taking into account potential EMF4. EMF is a form of electromagnetic interference (EMI) that can affect the performance and reliability of the ICT equipment5. The closer the isolation transformer is to the ICT equipment, the shorter the cable length and the lower the voltage drop and power loss4. However, the isolation transformer should also be far enough from the ICT equipment to avoid EMF, which can be reduced by using proper shielding, grounding, and spacing5.

The isolation transformer should not be installed as far away as possible to the ICT equipment, as option B suggests, because this would increase the cable length and the voltage drop and power loss4. The isolation transformer does not have to be installed within the power entry point of the building, as option C suggests, because this is not a requirement of the electrical code or regulation, and it may not be optimal for the data centre power system. The isolation transformer should not be installed within the rack in which the ICT equipment has been installed, as option D suggests, because this would increase the heat load and the noise level in the rack, and it may not fit in the rack space.


Q3.

Can Electro Magnetic Fields (EMF) cause data centre failures?

Answer: A


See the explanation below.

According to the EPI Data Centre Training Framework, EMF is a form of electromagnetic interference (EMI) that can disrupt or damage the normal operation of electronic devices, such as servers, network cables, and IT equipment1. High levels of EMF can be generated by power equipment, cell phones, microwaves, TV and radio signals, etc., and can cause data corruption, data loss, system malfunction, and crashes23. Therefore, EMF can cause data centre failures and affect the availability, performance, and security of the data centre. To prevent or mitigate EMF, data centres should follow the best practices for data centre design, layout, cabling, grounding, shielding, and testing14.


Q4.

Does shielded twisted pair network cabling provide protection against EMF from power cables?

Answer: C


See the explanation below.

Shielded twisted pair cables (STP) are Ethernet cables that feature additional protection against electromagnetic interference from external sources, such as radio waves, microwaves, or other network cables. This is achieved by wrapping each pair of wires with a conductive shield, usually made of foil or braided wire, and then enclosing the entire cable with another shield layer. However, this shielding is not effective against low frequency electromagnetic fields (EMF) from power cables, which can induce currents and voltages in the network cables and cause signal distortion or data loss. Low frequency EMF can only be reduced by increasing the distance between the power and network cables, or by using a tre-foil cable arrangement, which is a special configuration of three power cables twisted together to cancel out the magnetic fields they generate.


Q5.

The temperature and humidity values indicated on the display of the Computer room air conditioner unit are the values measured at which point?

Answer: B


See the explanation below.

According to the IBM document on temperature and humidity design criteria1, the temperature and humidity values indicated on the display of the computer room air conditioner unit are the values measured at the intake of the air conditioner. This is because the intake is where the air conditioner draws the air from the computer room and cools and dehumidifies it before sending it back to the computer room. The display shows the current conditions of the computer room air, which are used to adjust the cooling and dehumidifying operations of the air conditioner. The values measured at the exhaust (outlet) of the air conditioner are not displayed, as they are not relevant for the computer room environment. The values measured at the front of the rack of the aisle the air conditioner is situated are also not displayed, as they may vary depending on the distance and location of the rack. The average value between the intake and exhaust (outlet) of the air conditioner is not displayed, as it does not reflect the actual conditions of the computer room air or the air conditioner performance.


Are You Looking for More Updated and Actual Exin CDCP Exam Questions?

If you want a more premium set of actual Exin CDCP Exam Questions then you can get them at the most affordable price. Premium Data Centre Professional exam questions are based on the official syllabus of the Exin CDCP exam. They also have a high probability of coming up in the actual Certified Data Centre Professional Exam .
You will also get free updates for 90 days with our premium Exin CDCP exam. If there is a change in the syllabus of Exin CDCP exam our subject matter experts always update it accordingly.